Always break a vacuum with dry nitrogen._ ! WARNING ELECTRICAL SHOCK HAZARD Deep Vacuum Method Failure to follow this warning could result in personal injury or death.
#Carrier air conditioners manuals manual
See Service Manual for triple evacuation method. The alternate triple evacuation method may be used. Refrigerant tubes and indoor coil should be evacuated using the recommended deep vacuum method of 500 microns. Table 2 – Accessory Usage Accumulator REQUIRED FOR LOW - AMBIENT COOLING APPLICATIONS (Below 55☏/12.8_C) No Compressor Start Assist Capacitor and Relay} Standard on 24ANA7 models.

On Infinity communicating systems only, for both 24ANA1 and 24ANA7 models, low ambient cooling is available to 0_F/-17.78_C. ! Operating Ambient UNIT DAMAGE HAZARD The minimum outdoor operating ambient in cooling mode is 55_F/12.78_C without low ambient cooling enabled, and the maximum outdoor operating ambient in cooling mode is 125_F/51.67_C. On rooftop applications, locate unit at least 6 in.

Leave some slack between structure and unit to absorb vibration. Run refrigerant tubes as directly as possible by avoiding unnecessary turns and bends. Ensure that vapor and liquid tube diameters are appropriate for unit capacity. where unit operation sound may disturb customer. Locate unit away from windows, patios, decks, etc.
#Carrier air conditioners manuals series
Information that is unique to the 24ANA1 series will be identified as such likewise information that is unique to the 24ANA7 series will also be identified.ĤANA INSTALLATION RECOMMENDATIONS NOTE: In some cases noise in the living area has been traced to gas pulsations from improper installation of equipment. Unless otherwise noted, information in these installation instructions pertain to both 24ANA1 and 24ANA7 series units. 24ANA Infinityt Series Air Conditioners with Puronr Refrigerant 2 to 5 Nominal Tons (Sizes 24 to 60) Installation Instructions NOTE: Read the entire instruction manual before starting the installation.